Thermocouple Extension wire type KCA-FG/FG-2*4/0.65
Specification:
1.SUBJECT
Fiberglass braided insulated thermocouple wire, 2×4/0.65mm, stranded wire, standard tolerances
and color code.
2.TECHNICAL FEATURES
A. Conductors:
Stranded thermocouple extension wire
Conductors Size(AWG) |
NO.of Strands &Gauge |
22 |
4/0.65mm |
B. Insulation:
Braided fiberglass (400ºC)
Nominal Insulation Thickness |
0.23 mm±0.2 |
Color code
Positive |
Color |
Negative |
Color |
Iron |
Red |
Copper-Nickel |
White |
C. Assembly:
Two conductors (positive and negative) parallel construction.
D. Overall Jacket
Braided fiberglass (400ºC)
Nominal Insulation Thickness |
0.25mm±0.2mm |
Color code |
Blue or White trace |
3, DIMENSIONS AND TOLERANCES
Dimensions/tolerances(mm) |
2.60±0.2×4.2±0.2 |
4, CALIBRATION TOLERANCE
Temperature range |
Standard tolerance |
Special tolerance |
0ºC to 400ºC |
±2.2ºC or 0.75% |
±1.1ºC or 0.4% |
Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other compensating
cable like KCA, KCB and so on.
Besides those wires, we can also produce according to your demand.