Installation Type: | Available |
---|---|
Sensing Type: | Thermocouple |
Contact: | Contact/Contactless |
Output Signal Type: | Digital Type |
Production Process: | Available |
Material: | Ceramic/Aluminun/Stainless Steel... |
Customization: |
---|
Suppliers with verified business licenses
MICC Thermocouple with metallic protection tube Can be combined with various types of materials for protection tubes, which prolong the life of the sensor
Technical Data Sheet:
Type of Thermocouple Core | |||||||
Material Type |
Leg | core material |
Leg dia | JIS C 1602 | ANSI | ||
JIS | ANSI | Max.operating temp . In normal application(ºC) |
Max.operating temp . In overheated application(ºC) |
Max.operaring temp.(ºC) |
|||
B | + | Platinum 70% + rhodium 30% | 0.5 | 0.5 | 1500 | 1700 | 1700 |
- | Platinum 94% + rhodium 6% | 0.5 | 0.5 | ||||
R | + | Platinum 87% + rhodium 13% | 0.5 | 0.5 | 1400 | 1600 | 1480 |
- | high purity platinum | 0.5 | 0.5 | ||||
S | + | Platinum90%+ rhodium 10% | 0.5 | 0.5 | |||
- | high purity platinum | 0.5 | 0.5 | ||||
K | + | Nickel 90% + chromiun 10% Nickel 95% + Manganese 2% +Aluminum 2% |
3.2 | 3.2 | 1000 | 1200 | 1260 |
2.3 | 1.6 | 900 | 1100 | 1090 | |||
1.6 | 0.8 | 850 | 1050 | 980 | |||
1 | 0.5 | 750 | 950 | 870 | |||
0.65 | 0.32 | 650 | 850 | 870 | |||
E | + - |
Nickel 90% +chromiun 10% Copper 55%+nickel 45 % |
3.2 | 3.2 | 700 | 800 | 870 |
2.3 | 1.6 | 600 | 750 | 650 | |||
1.6 | 0.8 | 550 | 650 | 540 | |||
1 | 0.5 | 500 | 550 | 430 | |||
0.65 | 0.32 | 450 | 550 | 430 | |||
J | + - |
high purity iron Copper 55%+nickel 45 % |
3.2 | 3.2 | 600 | 750 | 760 |
2.3 | 1.6 | 550 | 750 | 590 | |||
1.6 | 0.8 | 500 | 650 | 480 | |||
1 | 0.5 | 450 | 650 | 370 | |||
0.65 | 0.32 | 400 | 500 | 370 | |||
T | + - |
high purity copper Copper 55%+nickel 45 % |
1.6 | 1.6 | 300 | 350 | 370 |
1 | 0.8 | 250 | 300 | 260 | |||
0.65 | 0.5 | 200 | 250 | 200 | |||
0.32 | 0.32 | 200 | 250 | 200 |
Suppliers with verified business licenses