Customization: | Available |
---|---|
Type: | Network Type |
Measuring Medium: | Temperature |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic parameter | Input | ||||
Voltage supply | 12~45VDC. | Measured | Temeprature | ||
variable | |||||
Power protection | Reverse polarity | Accuracy | 0.2% | ||
protection | |||||
Damping time | < 5S | Sensor type and | Refer to the following | ||
Dielectric | measuring range | Input type and range | |||
strength(power | 1500V,AC,1min | ||||
supply | terminals | Output | |||
between the shell) | |||||
Insulation | resistance | ||||
(between | the power | ||||
supply terminal, the | ≥100MΩ | Current output | 4~20mA | ||
input terminal and the | |||||
housing) | |||||
Load | RL≤(Ue-12)/0.022A | ||||
resistance | |||||
GB/T 17626.1-2006 | |||||
Electromagnetic | Upper and lower | ||||
GB/T 17626.2-2006 | |||||
compatibility | limit | overflow | |||
GB/T 17626.4-2008 | IH = 22mA ; IL= 3.8mA | ||||
alarm | output | ||||
current | |||||
Mini range | 50ºC | output | current of | 22mA | |
Weight | 46g | input break alarm |
Sensor | Type | Range | Output | ||
accuracy | |||||
Pt100 | -200ºC~+850ºC | 0.4ºC/0.2% | Configuration setting | ||
Cu50 | ºC~ | ºC | ºC | ||
-50 | +150 | 0.4 /0.2% | Setting euqipment: handheld | ||
(RTD) | Cu100 | -50ºC~+150ºC | 0.4ºC/0.2% | ||
communicator MICC300. | |||||
Ni100 | -100ºC~+260ºC | 0.4ºC/0.2% | |||
Ni120 | -60ºC~+200ºC | 0.4ºC/0.2% | |||
T | -200ºC~+400ºC | 1ºC/0.2% | |||
E | -200ºC~ | 1ºC/0.2% | |||
+1000ºC | |||||
J | -200ºC~ | 1ºC/0.2% | |||
+1200ºC | |||||
K | -200ºC~ | 1ºC/0.2% | Ambient temp condition | ||
+1370ºC | |||||
Storage temp::-30ºC~+80ºC | |||||
(TC) | -200ºC~ | ||||
N | 1ºC/0.2% | Working temp:-25ºC~+75ºC | |||
+1300ºC | |||||
Relative humidity:≤85% | |||||
R | 0ºC~+1770ºC | 2ºC/0.2% | |||
Standard temp:23ºC | |||||
S | 0ºC~+1770ºC | 2ºC/0.2% | |||
B | 0ºC~+1820ºC | 2ºC/0.2% | |||
Millivolt | -10mV~70mV | 40uV/0.2% | |||
Output | |||||
"Output Accuracy" take the bigger one of the | |||||
configuration scale errors. | |||||
★Reference condition: standard temp: 23ºC(73.4ºF)± 5ºC. |