Customization: | Available |
---|---|
Certification: | ISO9001, CE |
Type: | Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Nominal Resistance R0 | Tolerance DIN EN 60751 1996-07 | Tolerance DIN EN 60751 2009-05 | Order Number Plastic Box |
100 Ohm at 0º C | Class 1/3B | F 0.1 | 32 207 692 |
Class A | F 0.15 | 32 207 691 | |
Class B | F 0.3 | 32 207 690 | |
1000 Ohm at 0º C | Class B | F 0.3 | 32 207 695 |
Specification | DIN EN 60751 (according to IEC 751) |
Temperature range | -70º C to +500º C (continuous operation) (temporary use to 550º C possible) Tolerance Class B: -70º C to +500º C Tolerance Class A: -50º C to +300º C Tolerance Class 1/3 B: 0º C to +150º C |
Temperature coefficient | TCR = 3850 ppm/K |
Leads | Pt clad Ni- wire Recommended connection technology: Welding, Crimping and Brazing |
Lead lengths (L) | 10mm 1mm |
Long-term stability | max. R0-drift 0.04% after 1000 h at 500º C |
Vibration resistance |
at least 40g acceleration at 10 to 2000 Hz, depends on installation |
Shock resistance | at least 100g acceleration with 8ms half sine wave, depends on installation |
Environmental conditions | unhoused for dry environments only |
Insulation resistance | > 100 MΩ at 20º C; > 2 MΩ at 500º C |
Self heating | 0.6 K/mW at 0º C |
Response time | water current (v= 0.4m/s): t0.5 = 0.04s t0.9 = 0.12s air stream (v= 2m/s): t0.5 = 2.2s t0.9 = 7.0s |
Measuring current | 100Ω : 0.3 to 1.0 mA 1000Ω : 0.1 to 0.3 mA (self heating has to be considered) |
Note | Other tolerances, values of resistance are available on request. |