Customization: | Available |
---|---|
Type: | Available |
Conductor Type: | Stranded/Solid |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MICC MICC High Temperature Thermocouple Wire K-CERAMIC FIBER-2*20AWG with Two conductors parallel construction
Thermocouple Connector Detalis:
Conductor material:
This specification covers the requirements for Ceramic fiber braided insulated thermocouple wire, type KX, 2x0.8, standard tolerances and color coding .
2. TECHNICAL FE
A. Conductors:
Solid thermocouple grade wire
Conductor Size(AWG) |
No. of Strands & Gauge |
20 |
2*0.8 |
B. Insulation:
Braided fiberglass (0to1204ºC)
Nominal Insulation Thickness: 0.25mm
Positive |
Color |
Negative |
Color |
|
Ni-Cr |
White with green tracer |
Ni-Al |
white |
C. Assembly:
Two conductors (positive and negative) parallel construction.
D. Overall Jacket:
Fiberglass braided (0to1204ºC)
Nominal Insulation Thickness: 0.25mm
Color code : white with green trace
Dimensions / tolerances (mm) |
3.1±0.2 X1.73±0,2 |
Temperature range |
Standard tolerance* |
Special tolerance* |
0to1000ºC |
±2,2ºC or 0.75% |
±1,1ºC or 0,4% |
5. PACKING AND IDENTIFICATION
Package items carefully to avoid damage during shipment.
Color code table
IS, DIN and others are also available.