Customization: | Available |
---|---|
Installation Type: | Available |
Sensing Type: | Thermocouple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MICC Probe Type Thermocouple Pot Protects the connection between the mineral insulated cable and the wire assuring a reliable and durable measurement
Technical Data Sheet:
Type of Thermocouple Core | |||||||
Material Type |
Leg | core material |
Leg dia | JIS C 1602 | ANSI | ||
JIS | ANSI | Max.operating temp . In normal application(ºC) |
Max.operating temp . In overheated application(ºC) |
Max.operaring temp.(ºC) |
|||
B | + | Platinum 70% + rhodium 30% | 0.5 | 0.5 | 1500 | 1700 | 1700 |
- | Platinum 94% + rhodium 6% | 0.5 | 0.5 | ||||
R | + | Platinum 87% + rhodium 13% | 0.5 | 0.5 | 1400 | 1600 | 1480 |
- | high purity platinum | 0.5 | 0.5 | ||||
S | + | Platinum90%+ rhodium 10% | 0.5 | 0.5 | |||
- | high purity platinum | 0.5 | 0.5 | ||||
K | + | Nickel 90% + chromiun 10% Nickel 95% + Manganese 2% +Aluminum 2% |
3.2 | 3.2 | 1000 | 1200 | 1260 |
2.3 | 1.6 | 900 | 1100 | 1090 | |||
1.6 | 0.8 | 850 | 1050 | 980 | |||
1 | 0.5 | 750 | 950 | 870 | |||
0.65 | 0.32 | 650 | 850 | 870 | |||
E | + - |
Nickel 90% +chromiun 10% Copper 55%+nickel 45 % |
3.2 | 3.2 | 700 | 800 | 870 |
2.3 | 1.6 | 600 | 750 | 650 | |||
1.6 | 0.8 | 550 | 650 | 540 | |||
1 | 0.5 | 500 | 550 | 430 | |||
0.65 | 0.32 | 450 | 550 | 430 | |||
J | + - |
high purity iron Copper 55%+nickel 45 % |
3.2 | 3.2 | 600 | 750 | 760 |
2.3 | 1.6 | 550 | 750 | 590 | |||
1.6 | 0.8 | 500 | 650 | 480 | |||
1 | 0.5 | 450 | 650 | 370 | |||
0.65 | 0.32 | 400 | 500 | 370 | |||
T | + - |
high purity copper Copper 55%+nickel 45 % |
1.6 | 1.6 | 300 | 350 | 370 |
1 | 0.8 | 250 | 300 | 260 | |||
0.65 | 0.5 | 200 | 250 | 200 | |||
0.32 | 0.32 | 200 | 250 | 200 |